Data Centre Container

Catalogue 2014/2015

Data Centre Container System accessories Page 507 Fire protection: – Fire protection, internal panels: F30, optionally F90 based on DIN 4102/EN1363, component tested Duct system: – Type: Hard duct DN200 – Dimensions of packing space: 120 x 120 mm – Protected cable/tube entries Raised floor: – Optimised load distribution – Equipped with cable/tube routing – Variable ventilation panels with DFC Climate control: – Customised climate control variants – Targeted cooling via aisle containment – Energy-efficient DFC cooling (direct free cooling), with no additional external units – Powerful LCP cooling (liquid cooling package), with minimal space requirements Power distribution: – Infeed: CEE connector 125 A, 3-phase/N/PE, 400 V/50 Hz – Busbar system for rack-based power distribution Customised solutions: – Interlinked containers, other climate control variants Optional: – Up to seven TS-IT racks with power supply – Fire alarm/extinguisher system (Novec 1230) – Access systems, access door (keyboard, code card) – Monitoring and management (CMC, RiZone) for monitoring alarm, maintenance messages and customer-specific parameters Note: – Standard range of models with pre-configured data centre types – The Data Centre Container is configured on a project-specific basis Technical details: Available on the Internet Photo shows a configuration example with equipment not included in the scope of supply Type 1 2 3 4 5 6 7 8 9 Width mm 3000 Height mm 3250 Depth mm 6058 8000 10000 11500 6058 8000 10000 11500 9500 Useful area m2 15.2 20.4 25.7 29.7 15.2 20.4 25.7 29.7 20.4 Model No. 7857.998 Climate control, Direct Free Cooling/Liquid Cooling Packages DFC DFC DFC DFC LCP LCP LCP LCP LCP Max. cooling output kW 20 20 50 50 20 40 80 100 40 Redundancy cooling n+1 n+1 n+1 n+1 n+1 n+1 n+1 n+1 n+1 Heavy-duty raised floor ◾ ◾ ◾ ◾ ◾ ◾ ◾ ◾ ◾ Plug-and-play power distribution ◾ ◾ ◾ ◾ ◾ ◾ ◾ ◾ ◾ Hard ducts DN200 3 3 4 4 4 5 5 5 5 Security door, resistance class 2 ◾ ◾ ◾ ◾ ◾ ◾ ◾ ◾ ◾ Optional fittings DET-AC XL fire alarm/extinguisher system ◾ ◾ ◾ ◾ ◽ ◽ ◽ ◽ ◽ UPS (uninterruptible power supply) ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ Max. no. of racks 42 U (600 mm wide) without UPS 6 9 10 12 6 8 11 13 8 M ax. no. of racks 4 2 U (800 mm wide) without UPS 4 6 7 9 4 6 8 9 6 Higher racks (47 U) ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ Rack power supply ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ Monitoring package (CMC III) ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ RiZone package ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ Security door, resistance class 3 ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ Additional hard ducts for cable/pipe entry ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ Metal sun shade ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ ◽ Standard ◽ Option 472 Rittal Catalogue 34/IT infrastructure


Catalogue 2014/2015
To see the actual publication please follow the link above