Micro Data Centre - Level E

Catalogue 2014/2015

Micro Data Centre System accessories Page 507 Applications: ◾ A high level of protection against potential physical threats for IT ◾ Targeted configuration components complete it to a Micro Data Centre Benefits: ◾ As well as facilitating installation in poorly accessible sites, the modular design also makes it possible to retrospectively enclose existing IT structures ◾ Extendibility, dismantling and re-assembly mean targeted, future-safe investments ◾ Tested security – testing has been carried out by accredited institutes and confirmed with test reports Protection standards: – Fire protection category F 90 to DIN 4102 Part 2 – Compliance with limits ΔT < 50 K, rel. humidity < 85%, over 30 minutes – Burglar resistance WK II, III and IV, tool attack analogous to DIN V ENV 1630/1999-04/ WK II – Smoke protection based on DIN 18 095-2: 1991-03 Material: – Sheet steel, coated Colour: – Enclosure and service door: RAL 7035 – Operator door: RAL 9005 Protection category IP to IEC 60 529: – IP 56 Supply includes: – Micro Data Centre with operator door and service door – Cable entry in both side elements – Both doors with key lock Optional: – Choice of door hinges – Bifold doors – Different cable entry systems – Cable entry additionally in the top or base unit – Different lock variants – Supporting structure T1 1060 1060 T2 B1 H1 H2 B2 T3 Note: – The Micro Data Centre is configured on a project-specific basis Technical details: Available on the Internet Level E Units U 42 47 42 47 Page External dimensions mm Width (B1) 1100 1100 1100 1100 Height (H1) 2210 2410 2210 2410 Depth (T1) 1200 1200 1400 1400 Depth (T3) 3320 3320 3520 3520 Internal dimensions mm Width (B2) 920 920 920 920 Height (H2) 2030 2230 2030 2230 Depth (T2) 1000 1000 1200 1200 Model No. 7999.009 7999.009 7999.009 7999.009 Empty weight excluding cooling unit and excluding rack approx. kg 660 700 730 800 Accessories Network/server enclosures TS-IT see page see page see page see page 86 Fire alarm and extinguisher system DET-AC/EFD Plus see page see page see page see page 473 CMC monitoring system see page see page see page see page 446 PSM – Power System Module busbar see page see page see page see page 409 PDU – Power Distribution Unit see page see page see page see page 416 Climate control for micro data centre from page from page from page from page 469 LCP – Liquid Cooling Package, rack depth 1000 mm see page see page see page see page 428 Standard protection from: Fire Extinguishing water Corrosive gases Vandalism Unauthorised access Dust Theft/burglary 466 Rittal Catalogue 34/IT infrastructure


Catalogue 2014/2015
To see the actual publication please follow the link above