LCP Inline CW

Catalogue 2014/2015

Liquid Cooling Package Accessories for LCP Page 433 Chillers for IT cooling Page 441 Network/server enclosures TS-IT Page 92 Benefits: – Maximum energy efficiency thanks to EC fan technology and IT-based control – Minimal pressure loss at the air end, which in turn minimises the power consumption of the fans – Optimum adaptability due to dynamic, continuous control of the cold water volume flow – By using high water inlet temperatures, the proportion of indirect free cooling is increased, which in turn reduces operating costs – Targeted cooling output thanks to modular fan units – Fan modules configurable as n+1 redundancy – Standard 3-phase connection for electrical redundancy – With redundant temperature sensor integrated at the air end as standard – The separation of cooling and rack prevents the ingress of water into the server enclosure – Up to 55 kW cooling output on a footprint of just 0.36 m² – Minimal area load due to low weight Functions: The hot air is drawn in from the room or hot aisle at the rear of the device and expelled at the front into the cold aisle after cooling. The LCP achieves maximum performance and efficiency in conjunction with Rittal cold aisle containment. With this product, a raised floor is not necessary. Monitoring: – Monitoring of all system-relevant parameters such as server air intake temperature, server waste air temperature, water inlet/return temperature, water flow, cooling output, fan speed, leakage – Direct connection of the unit via SNMP over Ethernet – Integration into RiZone Temperature control: – Linear fan control – Two-way control valve Colour: – RAL 7035 Protection category IP to IEC 60 529: – IP 20 Cooling medium: – Water Optional: – Various sensors – Racks 2200 mm high Technical details: Available on the Internet Photo shows a configuration example with equipment not included in the scope of supply LCP Inline CW Model No. Packs of 3311.530 3311.540 3311.560 Page Total cooling output/Number of fan modules required kW 10 / 1 20 / 2 30 / 3 18 / 2 27 / 3 30 / 4 40 / 4 45 / 5 55 / 6 Number of fan modules in supplied state 1 2 4 Width mm 300 300 300 Height mm 2000 2000 2000 Depth mm 1200 1200 1200 Installation in bayed enclosure suite Set forward Flush Set forward Rated operating voltage V, ~, Hz 230, 1~, 50/60 400, 3~, 50/60 230, 1~, 50/60 400, 3~, 50/60 230, 1~, 50/60 400, 3~, 50/60 Type of electrical connection Connector Connector Connector Air throughput at max. cooling output m³/h 4800 4800 8000 Fans may be exchanged with the system operational ◾ ◾ ◾ EC fan ◾ ◾ ◾ Permissible operating pressure (p. max.) bar 6 6 6 Duty cycle % 100 100 100 Water connection 1½" external thread 1½" external thread 1½" external thread Water inlet temperature °C 15 15 15 Weight as delivered kg 214.0 221.0 235.0 Accessories Fan module 1 pc(s). 3311.011 3311.011 3311.011 434 Touchscreen display, colour 1 pc(s). 3311.030 3311.030 3311.030 433 Connection hose, bottom and top 2 pc(s). 3311.040 3311.040 3311.040 433 Add-on cover 1 pc(s). 3301.421 3301.421 3301.421 433 Rear adaptor 1 pc(s). 3311.080 – 3311.080 433 Rittal Catalogue 34/IT infrastructure 429


Catalogue 2014/2015
To see the actual publication please follow the link above