Configuration

Catalogue 2014/2015

Power Distribution Unit Configuration PDU version managed/ managed slave1) switched metered basic Mechanical May be fitted in the zero-U space in the 600 mm wide TS-IT, tool-free ◾ ◾ ◾ ◾ Colour coding of phases and fuse circuits (depending on PDU version) ◾ ◾ ◾ ◾ Connection cable, static, 3 m, with CEE connector (IEC 60 309) or C20 ◾ ◾ ◾ ◾ Connector lock for C13 and C19 pin patterns (optional) ◾ ◾ ◾ ◾ Lockable cover for slots that are not needed (for C13/C19) ◾ ◾ – – PDU slave version without display and Ethernet connection for use with PDU master and CMC III ◾ – – – Electrical Power supply 110 V – 230 V/400 V, inherent power consumption approx. 15 W ◾ ◾ ◾ – Rated current 16/32 A, single-phase/3-phase ◾ ◾ ◾ ◾ Version additionally 63 A/3-phase (blade PDU, no Zero-U) – – ◾ – Electromagnetic circuit-breaker, 16 A, type C (only with 32/63 A PDU versions) ◾ ◾ ◾ ◾ PDU self-supplied, no external power supply required ◾ ◾ ◾ – PDU power supply redundant across all phases (with 3-phase PDUs) ◾ ◾ ◾ – Emergency power supply to PDU web server via PoE (Power over Ethernet), remains accessible even in the event of a mains failure ◾ ◾ – – Switching function per output slot ◾ ◾ – – Sequential activation of the outputs once the power is resumed (avoids overload peaks) ◾ ◾ – – Switching states are saved even in the event of a power failure ◾ ◾ – – Bistable relays/minimal power consumption ◾ ◾ – – Grouping (joint switching of several outputs) ◾ ◾ – – Measurement functions Voltage (V), current (A), frequency (Hz) ◾ ◾ ◾ – Active power (kW), active energy (kWh), apparent power (kVA), apparent energy (kVAh) ◾ ◾ ◾ – Power factor (cos phi) ◾ ◾ ◾ – Zero conductor measurement/load imbalance detection ◾ ◾ ◾ – Fuse monitoring (with 32/63 A versions) ◾ ◾ ◾ – Measurement per phase or infeed – ◾ ◾ – Measurement per output slot ◾ – – – Measurement accuracy +/-1% (kWh) to IEC 50 430-1 ◾ ◾ ◾ – Connectivity/management functions Powerful 400 MHz CPU and Linux operating system (not with slave versions) ◾ ◾ ◾ – Graphic OLED display 128 x 128 pixels (RGB) with back-lighting and energy-saving mode (display of output data and basic IP configuration) ◾ ◾ ◾ – Position sensor for display rotation (and correct visualisation in the DCIM software RiZone) ◾ ◾ ◾ – Multi-colour LEDs (green/amber/red) to indicate switching states and limits per phase or infeed – ◾ – – Multi-colour LEDs (green/amber/red) to indicate switching states and limits per individual output slot ◾ – – – Settable limits (warning/alarm) ◾ ◾ ◾ – Operating hours meter, total and cyclical (resettable) ◾ ◾ ◾ – Ethernet connection (RJ 45) ◾ ◾ ◾ – USB A-port for firmware update and data logging functions ◾ ◾ ◾ – CAN bus interface (RJ 45) ◾ ◾ ◾ – Web server (HTTP, HTTPS, SSL, SSH) NTP, Telnet ◾ ◾ ◾ – TCP/IP v4 and v6, DHCP ◾ ◾ ◾ – SNMP v1, v2c and v3 ◾ ◾ ◾ – FTP/SFTP (update/file transfer) ◾ ◾ ◾ – E-mail forwarding in case of alarm (SMTP) ◾ ◾ ◾ – User administration including rights management ◾ ◾ ◾ – LDAP(S)/Radius/Active Directory connection ◾ ◾ ◾ – Syslog server connection (max. 4 servers) ◾ ◾ ◾ – Plug & play drivers in the Rittal RiZone DCIM software ◾ ◾ ◾ – MIB for linking into 3rd party software ◾ ◾ ◾ – Suitable for connection to Rittal CMC III system ◾ ◾ ◾ – CMC III CAN bus sensors may be connected for ambient monitoring (max. 4 sensors) ◾ ◾ ◾ – CMC III sensors that may be used: Temperature sensor, temperature/humidity sensor, infrared access sensor, vandalism sensor ◾ ◾ ◾ – Ambient conditions Operating temperature 0°C...+45°C 0°C...+45°C 0°C...+45°C 0°C...+45°C Storage temperature -25°C...+70°C -25°C...+70°C -25°C...+70°C -25°C...+70°C Ambient humidity % (non-condensing) 10 – 95 10 – 95 10 – 95 10 – 95 Protection category IP to IEC 60 529 IP 20 IP 20 IP 20 IP 20 1) Managed slave without display/network Rittal Catalogue 34/IT infrastructure 419


Catalogue 2014/2015
To see the actual publication please follow the link above