Busbar systems (100/185/150 mm) Contact hazard protection Packs of Model No. Page 1250 A 1600 A 2500 A 3000 A End covers for busbar supports 10 pc(s). 3083.000 – – – Busbar cover section, length 1 m for E-Cu 30 x 10 mm 10 pc(s). 3092.000 – – – 253 40 x 10 to 60 x 10 mm 10 pc(s). 3085.000 3085.000 – – Edge cover section for bar systems with 10 mm space between the strands, length 1 m for 1 busbar per conductor 10 pc(s). 9676.041 9676.041 – – 272 for 2 busbars per conductor 10 pc(s). – – 9676.052 9676.052 Side cover section for bar systems, to match the edge cover sections, length 1 m For busbar width 60 mm 10 pc(s). 9676.056 9676.056 9676.056 9676.056 80 mm 10 pc(s). 9676.058 9676.058 9676.058 9676.058 100 mm 10 pc(s). 9676.059 9676.059 9676.059 9676.059 A B B A A B Connection system, see page 257 (system accessories) Plate clamps for connecting laminated copper bars; no drilling required A For busbars mm Clamping area for laminated copper bars mm 257 30 x 10 34 x 10 3 pc(s). 3554.000 – – – 40 x 10 34 x 10 3 pc(s). 3559.000 – – – 50 x 10 34 x 10 3 pc(s). 3560.000 3560.000 – – 50 x 10 54 x 10 3 pc(s). 3562.000 3562.000 – – 60 x 10 34 x 10 3 pc(s). 3561.000 3561.000 – – 60 x 10 54 x 10 3 pc(s). 3563.000 3563.000 – – 80 x 10 65 x 10 3 pc(s). – 3460.500 – – Conductor connection clamps for 10 mm bar thickness Connection of round conductors1) Clamping area for mm² laminated copper bars mm 257 1 – 4 – 15 pc(s). 3555.000 3555.000 3555.000 3555.000 1 – 4 – 15 pc(s). 3455.500 3455.500 3455.500 3455.500 2.5 – 16 8 x 8 15 pc(s). 3456.500 3456.500 – – 16 – 50 10.5 x 11 15 pc(s). 3457.500 3457.500 – – 35 – 70 16.5 x 15 15 pc(s). 3458.500 3458.500 – – 70 – 185 22.5 x 20 15 pc(s). 3459.500 3459.500 – – System covers for conductor connection clamps and plate clamps B C D Width x depth mm 257 50 x 80 4 pc(s). 3086.000 – – – 100 x 80 4 pc(s). 3087.000 – – – 100 x 110 4 pc(s). 3090.000 – – – 200 x 80 4 pc(s). 3088.000 – – – 200 x 110 4 pc(s). 3091.000 – – – Inserted screw nuts M12, self-holding nuts with knurled ring for mounting NH slimline fuse-switch disconnectors E For drilled holes in busbars Ø 14.5 mm 30 pc(s). 3591.060 3591.060 – – 253 Connection plates for laminated copper bars F Connection of laminated copper bars 2 x 10 x 100 x 1.0 mm on a busbar system with two bars per conductor For laminated copper bars up to 2 x 10 x 32 x 1 mm 1 pc(s). – – 9676.747 273 2) 9676.7472) 2 x 10 x 63 x 1 mm 1 pc(s). – – 9676.7482) 9676.7482) 2 x 10 x 100 x 1 mm 1 pc(s). – – 9676.7492) 9676.7492) Direct connection terminals G For the connection of round conductors 95 – 300 mm2 (single or multi-wire) 1 pc(s). – – 9676.7302) 9676.7302) 273 1) Wire end ferrules should be used with fine and extra-fine wire conductors 2) The required screw connection must be ordered additionally according to the busbar width, see page 273 A B C 230 – 325 D E G F Rittal Catalogue 34/Power distribution 279


Catalogue 2014/2015
To see the actual publication please follow the link above