Page 79

Technical System Catalogue Ri4Power

Ri4Power Table 31: Rated currents Inc for air circuit-breakers – Mitsubishi Brand Mitsubishi In of protection category and cooling cross-section,ConnectionMinimum compartment dimensionsnc with considerationRated current I Type breaker ventilation ventilation 3-pole version 4-pole version connection kitsForcedForcedair circuit- IP 2X IP 2X IP 43 IP 54 IP 54 Width Height Width Height Top Bottom A A A A A A mm mm mm mm mm mm AE1000 1000 1000 1000 1000 1000 1000 600 6001) 600 6001) 1 x 60 x 10 1 x 60 x 10 AE1250 1250 1250 1250 1250 1250 1250 600 6001) 600 6001) 2 x 60 x 10 2 x 60 x 10 AE1600 1600 1600 1600 1600 1600 1600 600 6001) 600 6001) 2 x 60 x 10 2 x 60 x 10 AE2000 2000 2000 1900 1600 1600 1600 6002) 6001) 800 6001) 3 x 60 x 10 3 x 60 x 10 AE2500 2500 2500 2375 2000 2000 2000 6002) 6001) 800 6001) 3 x 100 x 10 3 x 100 x 10 AE3200 3200 3110 2880 2560 2560 1950 6002) 6001) 800 6001) 3 x 100 x 10 3 x 100 x 10 1) For the switch version as rack-mounted variant, a minimum compartment height of 800 mm must be observed due to safety clearances. 2) When connecting to a Flat-PLS busbar system, a minimum enclosure width of 800 mm is required. Table 32: Rated currents Inc for air circuit-breakers – Schneider Electric Brand Schneider Electric In air of protection category and cooling cross-section,ConnectionMinimum compartment dimensionsnc with considerationRated current I Type breaker ventilation ventilation 3-pole version 4-pole version connection kitsForcedForcedcircuit- IP 2X IP 2X IP 43 IP 54 IP 54 Width Height Width Height Top Bottom A A A A A A mm mm mm mm mm mm NW08 800 800 800 800 800 800 600 600 800 600 1 x 60 x 10 1 x 60 x 10 NW10 1000 1000 950 850 950 850 600 600 800 600 2 x 60 x 10 1 x 60 x 10 NW12 1250 1250 1130 770 1130 770 600 600 800 600 2 x 60 x 10 2 x 60 x 10 NW16 1600 1600 1520 1120 1280 1120 600 600 800 600 2 x 60 x 10 2 x 60 x 10 NW20 2000 1900 1720 1600 1900 1700 600 600 800 600 2 x 80 x 10 1 x 60 x 10 NW25 2500 2500 2150 1900 2150 1900 6001) 600 800 600 2 x 100 x 10 2 x 60 x 10 NW32 3200 3200 2500 2180 2500 2180 6001) 600 800 600 3 x 100 x 10 2 x 60 x 10 NW40 4000 3400 3120 2000 3120 1920 800 600 1000 600 3 x 120 x 10 3 x 60 x 10 2 x 2 x NW40b 4000 4000 3320 3010 3320 3010 1000 600 1200 600 3 x 80 x 10 3 x 80 x 10 1) When connecting to a Flat-PLS busbar system, a minimum enclosure width of 800 mm is required. Rittal Technical System Catalogue/Power distribution 2 - 78


Technical System Catalogue Ri4Power
To see the actual publication please follow the link above