Fuse designations, operating categories

Technical System Catalogue Ri4Power

Ri4Power Form 4a Separation between the busbars and function units and sepa- ration between the individual function units and separation between the connections for conductors fed in from the out- side that are assigned to a function unit, and the connections of all other function units, as well as the busbars. With Form 4a, however, the connections and the function unit are in one compartment. Form 4b Separation between the busbars and function units and sepa- ration between the individual function units and separation between the connections for conductors fed in from the out- side that are assigned to a function unit, and the connections of all other function units, as well as the busbars. With Form 4b, however, the connections and the function unit are like- wise separated. Explanation: Internal separation is met via compliance with protection category IP XXB. For protection against the ingress of solid foreign bodies, protection category IP 2X is a minimum requirement. Fuse designations, operating categories Table 21: Operating categories of fuse inserts D systems Designations DIAZED = diametrically graduated two-piece Edison fuse DII fusible element has an E27 electrical thread and All-range fuse currents up to 25 A gG/gL protection–> Overcurrent cable protection and short-circuit DIII fusible element has an E33 electrical thread and currents up to 63 A gM All-range fuse inserts for protecting motor circuits Application range RiLine60 aM Back-up fuse short-circuit protection for motor circuits in circuits D0 system gD All-range breaking capacity with delay NEOZED is a Siemens registered trademark D01 fusible elements have an E14 up to 16 A gN All-range breaking capacity without delay (with featherkey, may also be used in D02 elements) aR Back-up fuse, only short-circuit protection D02 fusible elements have an E18 electrical thread and for semi-conductor protection, high-speed can protect against short-circuits with currents up to 63 A gS All-range fuse, semi-conductor elements, high-speed Application range RiLine60 gR All-range fuse, semi-conductor protection high-speed, NH system faster than gS Low-voltage high-performance fuse gTr Transformer protection The sizes of the fuses are as follows: gB Protection for mining systems − NH 000 from 6 – 100 A − NH 00 from 6 – 160 A Table 22: Colour code for fuse inserts − NH 0 from 6 – 160 A (must no longer be used in new systems) Current Colour − NH 1 from 80 – 100 A 2 A Pink − NH 2 from 125 – 400 A − NH 3 from 315 – 630 A 4 A Brown − NH 4 from 500 – 1000 A 6 A Green − NH 4a from 500 – 1250 A 10 A Red Application range RiLine60 and Ri4Power 16 A Grey 20 A Blue 25 A Yellow 35 A Black 50 A White 63 A Copper 80 A Silver 100 A Red 125 A Yellow 160 A Copper 200 A Blue 2 - 73 Rittal Technical System Catalogue/Power distribution


Technical System Catalogue Ri4Power
To see the actual publication please follow the link above