Technical System Catalogue Climate Control

Project planning Page 82 Order information Catalogue 33, page 471 Enclosure heaters Enclosure heaters are used to prevent the formation of con- Fast assembly system: densation inside the enclosure and maintain a constant Quick terminal connection for power supply minimum operating temperature (e.g. when the system is Terminal suitable for parallel connection of an additional switched off overnight). heater Rittal TopTherm heaters, with self-regulating PTC technology, Minimal wiring work ensure constant heat distribution with outputs in the range; Superior efficiency: of 10 W – 150 W, for those not fitted with a fan and 250 W – Energy-saving self-regulating PTC technology 800 W for fan assisted variants. For heaters with fans, a Superior thermal output with an identical construction size minimum safety clearance of 300 mm at the top must be Constant distribution of heat observed, and the equivalent figure for heaters without fans Greater flexibility: is 100 mm. In each case the thermal safety clearance to the Output range: 10 – 800 W sides of 60 mm, and 100 mm at the bottom is required. Attachment on a 35 mm top hat rail or mounting plate Technical System Catalogue/Climate control 3 - 80